SSD の寿命を Linux で判断する
SSD(Intel X25-M)で寿命を確認するには at nkjmkzk.net
$ sudo smartctl -i /dev/sdc -d sat -a smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.18.0-13-generic] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: SATA SSD Serial Number: D61E076A1D2203758638 LU WWN Device Id: 5 000000 000000000 Firmware Version: SBFM10.6 User Capacity: 240,057,409,536 bytes [240 GB] Sector Size: 512 bytes logical/physical Rotation Rate: Solid State Device Form Factor: < 1.8 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: Unknown(0x0ff8) (minor revision not indicated) SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Tue Jan 29 00:20:22 2019 JST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (65535) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 4) minutes. Extended self-test routine recommended polling time: ( 32) minutes. Conveyance self-test routine recommended polling time: ( 8) minutes. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 100 100 050 Pre-fail Always - 0 9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 6907 12 Power_Cycle_Count 0x0012 100 100 000 Old_age Always - 4379 168 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 0 170 Unknown_Attribute 0x0003 093 093 010 Pre-fail Always - 180 173 Unknown_Attribute 0x0012 100 100 000 Old_age Always - 2490448 192 Power-Off_Retract_Count 0x0012 100 100 000 Old_age Always - 1372 194 Temperature_Celsius 0x0023 067 067 000 Pre-fail Always - 33 (Min/Max 33/33) 218 Unknown_Attribute 0x000b 100 100 050 Pre-fail Always - 0 231 Temperature_Celsius 0x0013 100 100 000 Pre-fail Always - 96 241 Total_LBAs_Written 0x0012 100 100 000 Old_age Always - 7107 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] SMART Selective self-test log data structure revision number 0 Note: revision number not 1 implies that no selective self-test has ever been run SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.
上の情報をどう読み取ればよいかわからなかったので、Windows 7 に CrystalDiskInfo をインストールして調べてみた。
「Crystal Disk Info」で、SSDの健康状態を把握しよう! | SSD徹底解説!
ただ、Wndows では ext4 が読み取れないので、下を参考に Ext2Fsd をインストールする。
ext4のパーティションをWindowsで読み書きする方法 | Linux Fan
以上の結果、下のように診断されました。
結果としては、Linux で smartctl を使ったのと同じ情報だが、なるほどこれはわかりやすい。
まだこの SSD は大丈夫みたいです。(2019/1/29)