SSD の寿命を Linux で判断する

SSD(Intel X25-M)で寿命を確認するには at nkjmkzk.net

$ sudo smartctl -i /dev/sdc -d sat -a
smartctl 6.6 2016-05-31 r4324 [x86_64-linux-4.18.0-13-generic] (local build)
Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Device Model:     SATA SSD
Serial Number:    D61E076A1D2203758638
LU WWN Device Id: 5 000000 000000000
Firmware Version: SBFM10.6
User Capacity:    240,057,409,536 bytes [240 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    Solid State Device
Form Factor:      < 1.8 inches
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   Unknown(0x0ff8) (minor revision not indicated)
SATA Version is:  SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Tue Jan 29 00:20:22 2019 JST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00)	Offline data collection activity
					was never started.
					Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(65535) seconds.
Offline data collection
capabilities: 			 (0x79) SMART execute Offline immediate.
					No Auto Offline data collection support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   4) minutes.
Extended self-test routine
recommended polling time: 	 (  32) minutes.
Conveyance self-test routine
recommended polling time: 	 (   8) minutes.

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000b   100   100   050    Pre-fail  Always       -       0
  9 Power_On_Hours          0x0012   100   100   000    Old_age   Always       -       6907
 12 Power_Cycle_Count       0x0012   100   100   000    Old_age   Always       -       4379
168 Unknown_Attribute       0x0012   100   100   000    Old_age   Always       -       0
170 Unknown_Attribute       0x0003   093   093   010    Pre-fail  Always       -       180
173 Unknown_Attribute       0x0012   100   100   000    Old_age   Always       -       2490448
192 Power-Off_Retract_Count 0x0012   100   100   000    Old_age   Always       -       1372
194 Temperature_Celsius     0x0023   067   067   000    Pre-fail  Always       -       33 (Min/Max 33/33)
218 Unknown_Attribute       0x000b   100   100   050    Pre-fail  Always       -       0
231 Temperature_Celsius     0x0013   100   100   000    Pre-fail  Always       -       96
241 Total_LBAs_Written      0x0012   100   100   000    Old_age   Always       -       7107

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]

SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.



上の情報をどう読み取ればよいかわからなかったので、Windows 7CrystalDiskInfo をインストールして調べてみた。
「Crystal Disk Info」で、SSDの健康状態を把握しよう! | SSD徹底解説!
ただ、Wndows では ext4 が読み取れないので、下を参考に Ext2Fsd をインストールする。
ext4のパーティションをWindowsで読み書きする方法 | Linux Fan
以上の結果、下のように診断されました。
20190129010121
結果としては、Linux で smartctl を使ったのと同じ情報だが、なるほどこれはわかりやすい。
まだこの SSD は大丈夫みたいです。(2019/1/29)